TM 10-3930-659-34 4-52. ACCUMULATOR PRECHARGE TEST. This Task Covers: Precharge Test Initial Setup: Equipment Conditions: Materials/Parts: Parking brake set (see TM 10-3930-659-10). Four preformed packings Frame  locking bar installed (see TM 10-3930- 659-10). Personnel Required:  Two Left side cab skirt removed (see TM 10-3930- References: 659-20). Hydraulic system warmed to operating temperature TM 10-3930-659-10 (see paragraph 2-28). TM 10-3930-659-20 Tools/Test Equipment: General mechanic's tool kit (Item 71, Appendix E) Adapter (Item 1, Appendix E) Adapter (Item 3, Appendix E) Quick coupler (Item 18, Appendix E) Pressure gage (Item 31, Appendix E) Hose assembly (Item 37, Appendix E) Tee (Item 63, Appendix E) PRECHARGE TEST WARNING Pressure  stored  in  accumulator  Is  approximately  500  psi  (3448  kPa).    Ensure  that accumulator    pressure    Is    relieved    before    removing    service    brake    hoses    or components.  Failure to follow this warning may result in serious injury or death to personnel. NOTE It is necessary to hold boot of one brake pedal with hand while opposite brake pedal is pumped.  Movement inside boot will be felt as opposite brake pedal is pumped. Accumulator pressure is relieved when movement stops. Each brake pedal should be pumped a full 75 times even if no movement is felt after pumping brake pedal several times. 1. Hold boot (3) of left brake pedal (4) with hand and pump right brake pedal (1) 75 times.  Release boot. 4-192