TM 10-3930-659-34
4-10.
FLYWHEEL HOUSING REPLACEMENT (Cont).
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame
or excessive heat. The solvent's flash point is 100°F-138°F (380C-590C). If you
become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts eyes, immediately wash your eyes and get medical aid.
1.
Using putty knife and dry cleaning solvent, remove gasket material from mounting surface of flywheel housing and
engine block.
2.
Clean all metal parts with dry cleaning solvent and dry with clean rags.
3.
Inspect flywheel housing for damage. Replace damaged flywheel housing.
4.
Inspect threaded parts for damaged threads. Repair damaged threads using tap and die threading set.
c.
INSTALLATION
1.
If removed, install two pins (8) and pipe plug (7)
in flywheel housing (2).
2.
If removed, install plug (5) and screw (6) in
flywheel housing (2).
TAT708088
4-48
|