TM 10-3930-659-20
17-29. HYDRAULIC RESERVOIR SUCTION FILTER REPLACEMENT (Con't).
b.
INSTALLATION
1.
Position hydraulic reservoir suction filter (1) in hydraulic reservoir (4) with bottom of suction filter over hole in
bottom of hydraulic reservoir.
2.
Push down on collar (2) and aline top of hydraulic reservoir suction filter (1) with hook (3). Release collar.
3.
Check that hydraulic reservoir suction filter (1) is firmly secured on hook (3).
FOLLOW-ON TASKS:
Fill hydraulic reservoir with hydraulic fluid (see TM 10-3930-659-10).
Install hydraulic reservoir filler cap and cover (see paragraph 17-35).
17-91
|