TM 10-3930-659-20
Table 4-2. Electrical Troubleshooting (Con't).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Check accessory relay within heater circuit of load center wiring harness for voltage and continuity (see
paragraphs 2-27 and 6-73).
Replace damaged accessory relay (see paragraph 6-12).
Step 3. Check heater blower control for continuity (see paragraph 2-27).
Replace damaged heater blower control (see paragraph 16-4).
Step 4. Disconnect left panel wiring harness at heater blower motor and test for 24 v at socket (see paragraph 2-27).
Replace damaged heater blower motor (see paragraph 16-12).
Step 5. Check wiring harnesses within heater circuits for continuity (see paragraphs 2-27 and 6-73).
Repair or replace damaged connector or wire (see paragraph 2-28).
24. DEFROSTER BLOWER MOTOR IS NOT WORKING.
Step 1. Check defroster fan fuse and defroster circuit fuse for continuity (see paragraph 2-27).
Replace damaged 10 amp fuse (see paragraph 6-13).
Replace damaged 15 amp fuse (see paragraph 6-13).
Step 2. Check accessory relay within defroster circuit of load center wiring harness for voltage and continuity (see
paragraphs 2-27 and 6-73).
Replace damaged accessory relay (see paragraph 6-12).
Step 3. Check defroster blower control for continuity (see paragraph 2-27).
Replace damaged defroster blower control (see paragraph 16-4).
Step 4. Disconnect left panel wiring harness at defroster blower motor and test for 24 v at socket (see paragraph 2-
27).
Replace damaged defroster blower motor (see paragraph 16-2).
Step 5. Check wiring harnesses within defroster circuits for continuity (see paragraphs 2-27 and 6-73).
Repair or replace damaged connectors or wires (see paragraph 2-28).
25. FRONT WINDSHIELD OR REAR WINDOW WIPER MOTOR IS NOT WORKING.
Step 1. Check front windshield/rear window wiper motor and washer fuse for continuity (see paragraph 2-27).
Replace damaged 10 amp fuse (see paragraph 6-13).
4-35
|