TM 10-3930-659-20
17-2.
FORK/BRAKE HYDRAULIC PUMP FLOW TEST.
This Task Covers: Flow Test
Initial Setup:
Equipment Conditions:
Materials/Parts:
Parking brake set (see TM 10-3930-659-10).
Rags (Item 27, Appendix C)
Frame locking bar installed (see TM 10-3930-
(659-10)
Tools/Test Equipment:
Hydraulic system warmed to operating temperature
(see paragraph 2-29).
General mechanic's tool kit (Item 44, Appendix F)
Right side cab skirt removed (see paragraph 14-6).
Adapter (Item 2, Appendix F)
Right transmission side guard removed (see para-
Hose assembly (Item 20, Appendix F)
graph 14-7).
Plug (Item 25, Appendix F)
Hydraulic tester (Item 41, Appendix F)
Personnel Required: Two
References:
TM 10-3930-659-10
NOTE
A suitable container should be used to catch any draining hydraulic fluid. Ensure that all
spills are properly cleaned.
FLOW TEST
WARNING
Pressure stored In accumulator Is approximately 500 psi (3448 kPa). Ensure that
accumulator pressure Is relieved before removing service brake hoses or components.
Failure to follow this warning may result In serious Injury or death to personnel.
NOTE
It Is necessary to hold boot of one brake pedal with hand while opposite brake pedal
is pumped. Movement inside boot will be felt as opposite brake pedal Is pumped.
Accumulator pressure Is relieved when movement stops.
Each brake pedal should be pumped a full 75 times even If no movement Is felt after
pumping brake pedal several times.
1.
Hold boot (3) of left brake pedal (4) with hand and pump right brake pedal (1) 75 times. Release boot.
17-6
|