TM 10-3930-659-20
17-1.
MAIN HYDRAULIC PUMP FLOW TEST (Con't).
10.
Close hydraulic tester (16) loading valve until pressure gage (12) reads 2000 psi (13790 kPa). Hydraulic tester
should Indicate a pump flow of 28 gpm (106 Ipm) or more. If pump flow is less than specification, check for
restrictions in hydraulic reservoir-to-main hydraulic pump hose or hydraulic reservoir suction filter. If no
restriction is found, replace main hydraulic pump (see paragraph 17-6).
11.
Shut down engine (see TM 10-3930-659-10).
12.
Remove pressure gage (12), hose (11), two fittings (9 and 10), and preformed packing (8) from tee (7). Discard
preformed packing.
13.
Remove hydraulic tester outlet hose (15), fitting (14), and preformed packing (13) from priority valve (2). Discard
preformed packing.
14.
Remove hydraulic tester inlet hose (17), fitting (18), and preformed packing (19) from tee (7). Discard preformed
packing.
15.
Remove tee (7), preformed packing (6), and fitting (5) from line (4). Discard preformed packing.
TA707611
17-4
|