16-18. DATA PLATES REPLACEMENT.
This Task Covers:
a.
Removal
b.
Installation
Initial Setup:
Materials/Parts:
Tools/Test Equipment:
Adhesive (Item 1, Appendix C)
General mechanic's tool kit (Item 44, Appendix F)
Rags (Item 27, Appendix C)
Electric drill, portable (Item 11, Appendix F)
Dry cleaning solvent (Item 31, Appendix C)
Twist drill set (Item 12, Appendix F)
Rivets (quantity will vary)
General Safety Instructions:
References:
Dry cleaning solvent is flammable and must not be
TM 10-3930-659-10
used near open flame. Use only in a well-ventilated
area.
NOTE
Refer to TM 10-3930-659-10 for location and description of all data plates.
a.
REMOVAL
NOTE
Perform step 1 only if data plate Is secured with rivets. Quantity of rivets may vary.
Loader frame data plate Is illustrated.
Perform steps 2 and 3 only if data plate Is secured with adhesive.
1.
Remove four rivets (3) and loader frame data plate (2) from loader frame (1). Discard rivets.