TM 10-3930-659-20
10-8.
SERVICE BRAKE RESIDUAL PRESSURE TEST (Cont).
NOTE
It Is necessary to hold boot of one brake pedal with hand while opposite
brake pedal Is pumped. Movement Inside boot will be felt as opposite brake
pedal is pumped. Accumulator pressure Is relieved when movement stops.
Each brake pedal should be pumped a full 75 times even if no movement is
felt after pumping brake pedal several times.
1.
Hold boot (3) of left brake pedal (4) with hand
and pump right brake pedal (1) 75 times.
Release boot.
2.
Hold boot (2) of right brake pedal (1) with hand
and pump left brake pedal (4) 75 times.
Release boot.
3.
Remove hose (5) and preformed packing (6) from tee (9). Discard preformed packing.
4.
Install two preformed packings (10 and 12) on tee (11).
5.
Install quick coupler (13) and adapter (14) on tee (11).
6.
Install tee (11) on tee (9).
7.
Install hose (5) on tee (11).
8.
Install hose (7) and pressure gage (8) on adapter (14).
9.
Start engine and allow brake system pressure to reach operating pressure (see TM 10-3930-659-10).
10.
Shut down engine (see TM 10-3930-659-10).
TA706943
10-22
|