10-8.
SERVICE BRAKE RESIDUAL PRESSURE TEST.
This Task Covers: Pressure Test
Initial Setup:
Equipment Conditions:
Materials/Parts:
Parking brake set (see TM 10-3930-659-10).
Three preformed packings
Frame locking bar installed (see TM 10-3930-
659-10).
Personnel Required: Two
Front cab skirt removed (see paragraph 14-6).
Hydraulic system warmed to operating
References:
temperature
(see paragraph 2-29).
· TM 10-3930-659-10
Tools/Test Equipment:
General mechanic's tool kit (Item 44, Append-
ix F)
Adapter (Item 2, Appendix F)
Quick coupler (Item 10, Appendix F)
Pressure gage (Item 18, Appendix F)
Hose assembly (Item 20, Appendix F)
Tee (Item 39, Appendix F)
NOTE
Service brake residual pressure test Is performed for both right and left brake
valves the same way. Right brake valve Is Illustrated.
If service brake residual pressure test Is performed for one brake valve,
procedure MUST be repeated for other brake valve.
PRESSURE TEST
WARNING
Pressure stored in accumulator Is approximately 500 psi (3448 kPa). Ensure
that accumulator pressure Is relieved before removing service brake hoses or
components. Failure to follow this warning may result in serious Injury or
death to personnel.
10-21
|