TM 10-3930-659-20
7-13.
TRANSMISSION THERMAL BYPASS VALVE MAINTENANCE (Con't).
c.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, Is toxic and flammable. Always wear protective
goggles and gloves, and use only In a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open
flame or excessive heat. The solvent's flash point is 100°F-138°F (38°C-590C).
If you become dizzy while using cleaning solvent, Immediately get fresh air
and medical help. If solvent contacts eyes, immediately wash your eyes and
get medical aid.
1.
Clean parts with dry cleaning solvent and dry with clean rags.
2.
Inspect parts for damage. Replace damaged parts.
d.
ASSEMBLY
1.
Install new seal (18), new valve element (16), and new spring (19) on valve body (17).
2.
Install two new preformed packings (15) on end caps (11).
3.
Install two end caps (11) on valve body (17) with four screws (14) and nuts (20).
4.
Install two new preformed packings (21) and elbow (22) on valve body (17).
5.
Install four new preformed packings (12) and two adapters (13) on end caps (11).
7-41
|