TM 10-3930-659-20
7-11.
TRANSMISSION CLUTCH CUTOFF VALVE MAINTENANCE (Con't).
c.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, Is toxic and flammable. Always wear protective goggles and
gloves, and use only In a well-ventilated area. Avoid contact with skin, eyes, and clothes, and
DO NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvent's flash
point Is 100°F-138OF (380C-590C). If you become dizzy while using cleaning solvent,
Immediately get fresh air and medical help. If solvent contacts eyes, Immediately wash your eyes
and get medical aid.
1.
Clean parts with dry cleaning solvent and dry with clean rags.
2.
Inspect parts for damage. Replace damaged parts.
d.
ASSEMBLY
1.
Install two new preformed packings (14 and 16) and adapters (15 and 17) on valve body (18).
2.
Install new preformed packing (13) and plug (12) on valve body (18).
3.
Install new preformed packing (11) and elbow (10) on valve body (18).
4.
Install new preformed packing (19) and solenoid valve (20) on valve body (18).
5.
Install new preformed packing (21) and coil (22) on solenoid valve (20) with new preformed packing (23), washer
(24), and nut (25).
7-33
|