TM 10-3930-659-20
2-27.
MULTIMETER (Con't).
c.
Measuring DC Voltage.
(1)
Set multimeter ON/OFF switch (4) to ON position.
(2)
Press VOLTS FUNCTION switch (1).
(3)
Set AC/DC selector switch (3) to DC.
(4)
Select and press LOWEST VOLTAGE/OHMS selector switch (6) for voltage range higher than the volts
to be measured.
(5)
Connect red probe (9) to positive (+) side of circuit and black probe (8) to negative (-) side of circuit.
(6)
Read digital readout (7) and interpret the results as DC voltage in the circuit being tested.
2-28.
ELECTRICAL REPAIR.
a.
General. Specific electrical system maintenance tasks are covered in Chapter 6 of this manual. The
following are general electrical practices and procedures.
TA706725
2-20
|