TM 10-3930-659-20 6-47. SLAVE RECEPTACLE REPLACEMENT (Con't). b. INSTALLATION 1. Position plastic Insulator (17) and slave receptacle (18) on right engine lower sideshield (10). 2. Install chain (11) on cap (13) with new lockwasher (14) and screw (15). 3. Install plastic insulator (16) and chain (11) on right engine lower sideshield (10) with four screws (12), washers (5), and nuts (4). 4. Install ground cable (3) on slave receptacle (18) with new lockwasher (2) and screw (1). 5. Install cable (6) on slave receptacle (18) with new lockwasher (7) and screw (8). 6. Install rubber boot (9) over battery cable (6). 7. Apply sealant on slave receptacle (18), two screws (1 and 8), and rubber boot (9). FOLLOW-ON TASKS: Close right engine upper sideshield (see TM 10-3930-659-10). Install conveyorized fork attachments to side of forklift truck (see paragraph 17-13). Connect negative battery cables (see paragraph 6-43). 6-163