TM 10-3930-659-20
6-47.
SLAVE RECEPTACLE REPLACEMENT.
This task covers:
a.
Removal
b.
Installation
Initial Setup
Equipment Conditions:
Materials/Parts:
Battery disconnect switch in OFF position (see
Sealant (Item 29, Appendix C)
TM 10-3930-659-10).
Marker tags (Item 33, Appendix C)
Negative battery cables disconnected -
Three lockwashers
(see para graph 6-43).
Conveyorized fork attachments removed from
References:
side of forklift truck (see paragraph 17-13).
TM 10-3930-659-10
Right engine upper sideshield opened
(see TM 10-3930-659-10).
Tools/Test Equipment:
General mechanic's tool kit (Item 44, Appendix F)
a.
REMOVAL
1.
Remove sealant from rear of slave receptacle
(18).
2.
Pull back rubber boot (9) and remove screw (8),
lockwasher (7), and cable (6) from slave
receptacle (18). Discard lockwasher.
3.
Remove screw (1), lockwasher (2), and ground
cable (3) from slave receptacle (18). Discard
lockwasher.
TA707839
6-161
|