TM 10-3930-659-20
6-45.
BATTERY DISCONNECT SWITCH GROUND STRAP REPLACEMENT (Con't).
b.
INSTALLATION
1.
Install battery disconnect switch ground strap (3) on battery disconnect switch (4) with new lockwasher (5) and
nut (6).
2.
Install battery disconnect switch ground strap (3) on starter motor ground terminal (1) with nut (2).
FOLLOW-ON TASKS:
Close right engine upper sideshield (see TM 10-3930-659-10).
Install conveyorized fork attachments on side of forklift truck (see paragraph 17-13).
Connect negative battery cables (see paragraph 6-43).
TA707836
6-158
|