TM 10-3930-659-20 6-44. STARTER MOTOR GROUND CABLE REPLACEMENT. This task covers: a. Removal b. Installation INITIAL SETUP: Equipment Conditions: Materials/Parts: Negative battery cables disconnected (see para- Marker tags (Item 33, Appendix C) graph 6-43). Conveyorized fork attachments removed from side of References: forklift truck (see paragraph 17-13). TM 10-3930-659-10 Right engine upper sideshield opened (see TM 10- 3930-659-10). Tools/Test Equipment: General mechanic's tool kit (Item 44, Appendix F) a. REMOVAL NOTE All leads should be tagged before removal.  Refer to paragraph 2- 18 for tagging Instructions. 1. Remove nut (3), ground strap (2), two terminal leads (8), and starter motor ground cable (1) from starter motor ground terminal (9). TA707833 6-155