TM 10-3930-659-20
2-27.
MULTIMETER (Con't).
CAUTION
Before performing a continuity test, always disconnect the forklift truck battery ground
cable and the circuit to be tested. Failure to follow this caution may damage the
multimeter.
(3)
Testing for Shorts. A short (or short
circuit) occurs when two circuits that should not be con-
nected have metal-to-metal contact with each other. A
short also occurs when a circuit that should not touch
ground has metal-to-metal contact with ground.
TESTING FOR SHORTS
(a)
Zero multimeter [see subparagraph (1)].
(b)
Connect black probe (8) to one circuit and red probe (9) to either a ground or another circuit.
(c)
Read digital readout (7) and interpret the results as follows:
1.
If digital readout (7) indicates 0 (zero), circuits are shorted or circuit is grounded if testing to
ground.
2.
If digital readout (7) does not indicate 0 (zero), circuits are not shorted.
3.
If digital readout (7) jumps or flickers, circuits are shorted or grounded intermittently.
TA706723