TM 10-3930-659-20
6-38.
WARNING BUZZER REPLACEMENT (Con't).
b.
INSTALLATION
1.
Install warning buzzer (6) on fault monitor console (7) by turning clockwise.
2.
Connect warning buzzer connector (5) to fault monitor and dash wiring harness connector (4).
CAUTION
Use care not to overtighten screws when installing dash plate. Dash plate Is
plastic and may be damaged if screws are overtightened.
3.
Install dash plate (3) on dash housing (1) with four screws (2).
TA707824
6-141
|