TM 10-3930-653-14&P
SECTION II.
MAINTENANCE
2.1 Maintenance Concept:
a.
The 4000 lb TCM America Model FG30N7(T) will not require special or new maintenance considerations.
Maintenance operations can be accomplished within the current maintenance support concept for Material Handling
Equipment (MHE).
b.
Nature and Extent of Maintenance:
(1)
Maintenance Allocation Chart (MAC): Maintenance will be performed as indicated in the MAC,
SECTION V, to retain and/or restore serviceablilty. Units may exceed their authorized scope and function in the MAC when
approved by appropriate commander.
(2)
Operator Maintenance: Operator maintenance is limited to daily preventive maintenance checks and
routine servicing SECTICN VIII.
(3)
Organizational Maintenance: Organizational maintenance consists of scheduled preventive
maintenance services, limited replacement,minor repair and adjustments SEQTION VIII.
(4)
Direct Support Maintenance: Direct support maintenance consists of repairs on-site and for return to
the user of the end item/assemblies which can be maintained efficiently with a minimum of tools and test equipment.
(5)
General Support Maintenance: General support maintenance will overhaul and repair for return to the
supply system those items designated by the Area Support Commander.
(6)
Depot Maintenance: There is no scheduled maintenance for the forklift at this level.
c.
Maintenance Expenditure Limit (MEL): The maintenance expenditure limit is based on a life expectancy of 11
years. Repair limits are based on 50% of replacement cost for the first 7 years and 30% for the last 4 years.
2.2 Reliability, Availability and Maintainability (RAM): Reliability, availability and maintainability will be assessed through
field evaluation of current users. Specific numberical RAM requirements or objectives are not established.
2.3 Modifications: Corrections or malfunctions that require modification of the end item must have Government approval
prior to field implementation.
2.4 Equipment Improvement Recommendations (EIR): Equipment improvement recommendations will be submitted IAW
DA Pam 738-750.