Cleanliness is of extreme importance and an absolute
must in the repair and overhaul of this unit. Before
attempting any repairs, the exterior of the unit must be
thoroughly cleaned to prevent the possibility of dirt and
foreign matter entering the mechanism.
(1) Straighten tangs of 12 lock plates.
Fig. 4-403. Straightening Lock Plate Tangs
(2) Loosen reamer bolt lock nuts, and remove six lock
plates and 12 lock nuts.
Fig. 4-404. Removing Lock Nuts
(3) Remove 12 reamer bolts.
Fig. 4-405. Removing Reamer Bolts
(4) Remove ring gear from cross case.
Fig. 4-406. Removing Ring Gear
(5) Separate cross case into flange half and plain half.
Fig. 4-407. Disassembling Cross Case