TM 10-3930-653-14&P
Fig. 4-206. Components of Distributor
4-7-7-2. CHECK AND ADJUSTMENT
(1) CAP AND ROTOR HEAD
The cap and rotor head must be inspected at regular
intervals. If the cap is cracked or is leaking current,
replace with a new one.
(2) POINTS
Standard point gap isO.45 to 0.55 mm(O.018 to
0.022 in). Adjustment should be made by loosening point
screws. Gap gauge is required for adjustment.
Point
gap
must
be
checked
according
to
maintenance schedule.
When
point
surface
is
rough,
take
off
any
irregularities with fine sandpaper (No. 500 or 600) or with
a point file.
At this time, grease must be applied to camshaft
head and cam heel.
When wear on breaker points is noticeable, replace
the point set.
To replace, proceed as follows:
Fig. 4-207. Breaker
4-115
|