TM 10-3930-653-14&P
Set the variable resistor to the "MAX" position. Apply
current (turn on these witch), and reduce resistance
gradually. When resistance is reduced to a certain level.
the charge lamp goes off.
This level indicates the charge relay operating
voltage. The rated value is 3.7 to 5.7V volts. When not
correct. readjust. The adjustment is carried out in the
same manner as the voltage regulator
Fig. 4-204. Charge Relay Operating
Voltage Measuring Circuit
(3) PRECAUTIONS FOR ADJUSTMENT
(1) Upon completion of adjustment, reinstall cover and
make sure that regulator operates correctly.
(2) When cover is removed or adjusting screw is
adjusted while adjusting voltage. be sure to disconnect
the regulator at once, and reconnect when actually
measuring or battery circuit may be short-circuited.
4-113
|