TM 10-3930-653-14&P
Fig. 4-200. Check Back Gap
(2) Adjusting the top air gap
Adjust
the
gap
by
bending
movable
contact
,supports,
Fig. 4-201. Adjusting Air Gap
(3) Adjusting the point gap
Adjust the gap b, bending secondary contact
support,
Fig. 4-202. Adjusting Point Gap
(4) Adjusting the voltage
Adjust the voltage be bending stopper up or down.
Bend upward to raise adjusting valve and down ward to
lower adjusting salve.
Fig. 4-203. Adjusting Voltage
(2) CHARGE RELAY
Unit. mm (n)
Model RLB2220B1
Back gap
0.75 to 1.1
(0.030 to 0.043)
Air gap
0.9 to 1.2
(0.035 to 0.047)
Point gap
0.75 to 1.1
(0.030 to 0.043)
The normal charge of a relay operating Is 3.7 to
5.7V at the generator "N" terminal.
It is difficult to measure this operating voltage with
the regulator mounted on the lift truck.
Prepare a battery, voltmeter and variable resistor,
and measure operating voltage after dismounting the
regulator.
4-112
|