TM 10-3930-653-14&P
(0.008
in)
from
commutator
surface,
commutator
(armature) should be turned on a lathe, so that the out-
of-roundness is less than 0 05 mm (0.0020 in) insulating
mica should also be undercut so that the depth of it is 0.5
to 0.8 mm (0.020 to 0 31 in).
Wear limit of the commutator diameter is, 2 mm
(0.08 in). It the commutator is beyond repair, replace.
Note
It is recommended to replace commutator as an
assembly if worn or damaged.
Fig. 4-162. Inspecting Commutator for
Out-of-Roundness
Fig. 4-163. Undercutting Insulating Mica
(3)
Inspect soldered connection of armature lead and
commutator. If loose connection is found, solder it using
rosing flux.
(4)Armature test for ground
Using a circuit tester, place one test probe onto
armature shaft and other onto each commutator bar.
If the tester shows continuity, the armature is
grounded and must be replaced
Fig. 4-164. Armature Test for Ground
(5)
Check armature for short by placing it on the
armature tester (growler) with a piece of iron over
armature core, rotating armature. If the plate vibrates,
armature is shorted
Fig. 4-165. Armature Test for Short-Circuit
(6)
Check armature for continuity by placing probes of
tester on two segments side by side. It tester shows no
continuity, circuit is open
4-98
|