C. INSTALLATION
6. Install outlet hose and by-pass hose or L.P.G.
converter hose on outlet elbow and secure
1. Clean all surfaces of the bypass line, and the
clamps.
thermostat.
CAUTION
2. Inspect upper and lower radiator hoses for any
Thermostat must be installed exactly
signs of deterioration. Replace if damaged.
as  it  was  removed  so  that  the
direction and heat of the coolant will
3. Use
non-hardening
gas ket
sealer
and
open it.
thoroughly cover all rubber hose connections.
NOTE
4. Properly position thermostat in water outlet
When filling the cooling system, care
elbow and install adapter ring.
should be taken to keep the coolant
clean to prevent any clogging of the
5. Assemble new gasket to cylinder head, position
cooling system or damage of the
water outlet elbow on studs, and secure with two
water pump.  Use only permanent
nuts and lockwashers (Figure 4-2).
antifreeze in connection with the
180 F. thermostats.
M-155-1