TM  10-3930-643-34 APPENDIX E (cont) d. Table E-4. Torque Limits for Tube Nuts. This  table  provides  tightening torques for tube nuts when tubes are flared to use 37 degree fittings. Torque limits given are for plain, cadmium, or zinc plated fittings for wet or dry installations. FITTING NO. THREAD  SIZE 4 5 6 8 10 12 14 16 20 24 32 7/16-20 1/2 -20 9/16-18 3/4 -16 7/8 -14 1-1/16-12 1-3/16-12 1-5/16-12 1-5/8 -12 1-7/8 -12 2-1/2 -12 TORQUE IN FOOT POUNDS 9 12 21 35 53 77 90 110 140 162 225 12 15 24 40 58 82 100 120 150 175 240 TORQUE IN  NEWTON METERS MIN. 12 16 29 47 72 104 122 149 190 217 305 MAX. 16 20 33 54 79 111 136 163 204 237 325 e. Table E-5. Torque Limits for Hydraulic Fittings. This table provides tightening  torques  for  preformed  packing,   boss  connectors  and  plugs,  37  degree seat  swivel  nuts  (fittings  and  hose),  and  locknuts  on  adjustable  fittings. FITTING NO. 4 5 6 8 10 12 14 16 20 24 32 TORQUE IN FOOT THREAD SIZE MIN. MAX. 7/16-20 1/2 -20 9/16-18 3/4 -16 7/8 -14 1-1/16-12 1-3/16-12 1-5/16-12 1-5/8 -12 1-7/8 -12 2-1/2 -12 6 10 15 25 35 60 70 80 95 120 250 10 15 20 30 40 70 80 90 115 140 300 TORQUE IN  NEWTON METERS MIN. 8 14 20 34 48 81 95 109 129 163 339 MAX. 14 20 27 41 54 95 109 122 156 190 407 E-3/(E-4 blank)