TM 10-3930-643-34
GENERAL SUPPORT TRANSMISSION MAINTENANCE.
15-3. Transmission Assembly. (Sheet 13 of 26)
CLEANING/INSPECTION
81.
82.
l
TOXIC/FLAMMABLE
Dry cleaning solvent P-D-680, used
for cleaning parts, is toxic and
flammable.
Use only in well
ventilated areas.
Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
used or stored.
Avoid contact
with eyes, skin or clothing. If
contact with eyes is made,
flush
with cold water and seek medical
attention immediately.
If contact
with skin or clothing is made,
flush with cold water.
If you
become dizzy while using cleaning
solvent,
get
fresh
air
immediately.
l
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
Use only with effective chip
guarding and personal protective
equipment (goggles/shield, gloves,
etc.).
NOTE
All parts should
cleaning to keep
assembly.
Clean all parts
P-D-680.
Dry
compressed air.
2-8.
be oiled after
them clean until
with cleaning solvent
thoroughly with
Refer to paragraph
Inspect all parts. Refer to para-
graph 2-9.
Go to sheet 14