TM 10-3930-643-34
HYDRAULIC SYSTEM TROUBLESHOOTING AND MAINTENANCE. (cont)
12-19.
Hydraulic Reservoir and Filter. (Sheet 2 of 11)
REMOVAL
1.
2.
3.
4.
NOTE
The following is a difference
between M10A Forklift models. The
removal/installation procedure is
identical.
Using a 9/16 socket and socket
wrench handle, remove four bolts (1),
washers (2) and plate (3) from left
side of hydraulic reservoir (35) on
vehicles S/N 2001 and above.
NOTE
All wire must be tagged when
removed from connector.
Indicate
whether wire is connected to pin-
type or socket-type connector.
Using slip joint pliers, disconnect
harness assembly (4) at connector.
Using a cross tip screwdriver, remove
four screws (5) and lock washers (6).
Disconnect harness assembly (7) at
connector.
Go to sheet 3