TM 10-3930-643-34
HYDRAULIC SYSTEM TROUBLESHOOTING AND MAINTENANCE. (cont)
12-12.
Lift Cylinder. (Sheet 10 of 10)
INSTALLATION
65.
66.
67.
68.
69.
70.
Check and refill hydraulic reservoir,
refer to TM 10-3930-643-12.
Operate engine until hydraulic fluid
is at normal operating temperature.
Move lift cylinder through at least
five full movements of travel to
bleed air from system.
Check for binding in lift cylinder
operation.
Stop engine.
Inspect hydraulic hoses, fittings and
cylinder assemblies for leaks. -
TESTING
71.
72.
73.
74.
75.
76.
Lower forks to the ground.
Using a 9/16 socket and socket wrench
handle, disconnect hoses from left
side lift cylinder and cap hoses.
Disconnect hose from lower end of right
side lift cylinder and cap hoses.
Operate engine at 2625 to 2750 rpm and
move lift control lever to maximum
LOWER position.
Observe lower port. Continuous fluid
flow from port indicates defective
packing. Replace packing if defective.
Connect hoses.
NOTE
Return M10A Forklift to
original equipment condition.
END OF TASK
12-110
|