TM 10-3930-643-34
HYDRAULIC SYSTEM TROUBLESHOOTING AND MAINTENANCE. (cont)
12-3.
Loader Control Valve. (Sheet 4 of
DISASSEMBLY
12.
Using a 1-1/2 socket and socket
wrench handle, remove plug (37) and
preformed packing (38) from outlet
housing (43).
Discard
preformed
packing (38).
13.
Using a 3/4 socket and socket wrenc
handle, remove two nuts (39), rod
(40), four nuts (41) and two rods
(42).
NOTE
When separating outlet housing and
valve assemblies be extremely
careful not to damage sealing
surfaces.
14.
Separate outlet housing (43), inlet
valve assembly (44), fork valve
assembly (45), tilt valve assembly
(46) and boom valve assembly (47).
15.
Using a scribe, remove and discard
four preformed packings (48).
NOTE
For repair of valve assemblies,
refer to paragraphs
12-4 thru
12-7.
Go to sheet 5
12-16
|