TM 10-3930-643-34
BRAKE TROUBLESHOOTING AND MAINTENANCE. (cont)
8-8.
Pressure Converter Reservoir (S/N 2001 and above). (Sheet 4 of 6)
CLEANING/INSPECTION
18.
19.
20.
Wipe diaphragm (16) with dry, clean
cloth .
l TOXIC/FLAMMABLE
Dry cleaning solvent P-D-680, used
for cleaning parts, is toxic and
flammable.
Use only in well
ventilated areas.
Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent
is
used or stored.
Avoid contact
with eyes, skin or clothing.
If
contact with eyes is made,
flush
with cold water and seek
medical
attention immediately.
If contact
with skin or clothing is
made,
flush with cold water.
If y ou
become dizzy while using cleaning
solvent,
get
fresh
air
immediately.
l COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
Use only with effective chip
guarding and personal protective
equipment (goggles/shield, gloves,
etc.).
Clean all other parts with cleaning
solvent P-D-680.
Dry thoroughly with
compressed air. Refer to paragraph
2-8.
Inspect all parts. Refer to para-
graph 2-9.
Go to sheet 5