| |
TM 10-3930-643-34
GENERAL MAINTENANCE PROCEDURES. (cont)
2-13.
Electrical Repair. (cont)
(b) TS-352 B/U.
1 Set FUNCTION switch (1) to DIRECT.
2 Put black lead (2) in LHMS-DC/± AC
jack.
3 To measure 24 volts DC,
plug red
lead (3) into 50V jack on left side
of meter.
(If measuring less than
10 volts DC, use 10V jack. If
measuring less than 2.5 volts DC,
use 2.5V jack).
(6) Measuring DC voltage.
To measure DC voltage, do the following steps:
(a) Set up and zero multimeter.
If you are unsure of the voltage to be
measured on the vehicle, always start on
the hightest range.
This will protect
the meter.
(b) Connect the red probe to the posi-
tive (+) side of the circuit and the black probe
to the negative (-) side.
The example shows 24
volts DC being measured across the batteries.
(c) Read the meter. If the needle moves
off scale to the left, reverse the probes on the
circuit.
NOTE
The following examples show how to read
both multimeters.
1 AN/URM-105.
Read the DC volts scale
for the range at which the selector
switch is set.
SWITCH SETTING
SCALE
1000 DC Volts
0-10 (and multiply by 100)
100 DC Volts
0-10 (and multiply by 10)
10 DC Volts
0-10 (read the number of scale)
1 DC Volts 0-10
(and divide by 10)
2-14
|