TM 10-3930-643-34
TRANSMISSION TROUBLESHOOTING AND MAINTENANCE. (cont)
6-6.
Transmission Assembly. (Sheet 7 of 12)
CLEANING/INSPECTION
45.
Wipe hose and tube assemblies
(13,
15, 17, 20, 22, 31, 34 and 37) with
clean cloth moistened with detergent
and water solution.
Wipe dry with
clean cloth.
TOXIC/FLAMMABLE
Dry cleaning solvent P-D-680, used
for cleaning parts, is toxic and
flammable.
Use only in well
ventilated areas. Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
used or stored.
Avoid contact
with eyes, skin or clothing.
If
contact with eyes is made,
flush
with cold water and seek
medical
attention immediately.
If contact
with skin or clothing is
made,
flush with cold water.
If you
become dizzy while using cleaning
solvent,
get
fresh
air
immediately.
46.
Wipe gage (4) with clean cloth
moistened with cleaning
solvent
P-D-680.
Allow to air dry.
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
Use only with effective chip
guarding and personal protective
equipment (goggles/shield, gloves,
etc.).
47.
Clean all other parts with cleaning
solvent P-D-680.
Dry thoroughly with
compressed air.
Refer to paragraph
2-8.
48.
Inspect all parts. Refer to para-
graph 2-9.
Go to sheet 8
6-42
|