TM 10-3930-643-34
TRANSMISSION TROUBLESHOOTING AND MAINTENANCE. (cont)
6-3.
Torque Converter. (Sheet 6 of 9)
CLEANING/INSPECTION
28.
Wipe hose assemblies (1, 2, 3, 8, 12,
29.
30.
31.
16 and 20) with clean cloth moistened
with detergent and water solution.
TOXIC/FLAMMABLE
Dry cleaning solvent P-D-680, used
for cleaning parts, is toxic and
flammable.
Use only in well
ventilated areas.
Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
used or stored.
Avoid contact
with eyes, skin or clothing.
If
contact with eyes is made,
flush
with cold water and seek medical
attention immediately.
If contact
with skin or clothing is
made,
flush with cold water.
If you
become dizzy while using cleaning
solvent,
get
fresh
air
immediately.
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
Use only with effective chip
guarding and personal protective
equipment (goggles/shield, gloves,
etc.).
Wipe
outer
surface of
torque
converter (28) with clean cloth
dampened with cleaning solvent
P-D-680.
Allow to air dry.
Clean all other parts with cleaning
solvent P-D-680.
Dry thoroughly with
compressed air.
Refer to paragraph
2-8.
Inspect all parts. Refer to para-
graph 2-9.
Go to sheet 7
6-16
|