TM 10-3930-643-34
TRANSMISSION TROUBLESHOOTING AND MAINTENANCE.
6-1.
Torque Converter Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a.
HIGH TORQUE CONVERTER OIL TEMPERATURE.
Step 1.
Transmission sump oil level too high or too low.
Add or drain to proper level, refer to LO 10-3930-643-12.
If oil level is correct, proceed to Step 2.
Step 2.
Check for foam in oil.
If there is evidence of foam, check for
leaks in torque converter lines, refer to paragraph 6-5.
If there is no leakage in lines, proceed to Step 3.
Step 3.
Test for torque converter pressure.
If
If
Step 4
pressure is low,
torque converter
check pump for wear.
pressure is accurate, proceed to Step 4.
.
Check for low oil flow through torque converter.
Replace torque converter charging pump, refer to paragraph 6-4.
Step 5. Check regulating valve for operation.
If not operating properly, refer to paragraph 4-10.
Step 6.
Check for clogged transmission oil cooler.
Remove and clean, refer to paragraph 6-9.
6-2
|