TM 10-3930-643-34
ELECTRICAL SYSTEM MAINTENANCE. (cont)
5-6.
Fork Control Wiring Harness. (Sheet
REMOVAL
NOTE
For the following procedures,
disconnect is used to indicate
the separation of plugs,
connectors or terminals and the
removal of all attaching
hardware.
To prevent loss,
reinstall attaching hardware in
its original position.
All electrical connections,
except those on the instrument
panel are sealed against
moisture with silicone sealant.
Remove all silicone sealant
before performing maintenance on
electrical connections.
The quantity of tie straps used
to secure harness is variable.
1.
Using diagonal cutting pliers, cut
and discard
tie
straps (1) in
operators compartment.
NOTE
All wire must be tagged when
removed from connector.
Indicate
whether wire is
connected to
pin-type or socket-type connector.
2*
Using a 1/2 socket and socket wrench
handle, remove clamp (2) from harness
assembly (13) in
left side of
operators compartment.
2 of 4)
GO to sheet 3
5-50
|