TM 10-3930-643-34
ELECTRICAL SYSTEM
5-3.
Main Wiring
MAINTENANCE. (cont)
Harness. (Sheet 11 of 15)
INSTALLATION (cont)
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
Using a flat tip screwdriver, connect
wire assembly (52) at terminal
and
two wire assemblies (51) at terminals
to hydraulic filter head.
Apply silicone sealant over entire
connection.
Using a 7/16 open end wrench,
connect
wire
assembly (50) at
terminal to mounting bracket.
Apply silicone sealant over entire
connection.
Using 1/2 and
3/8
open
end
wrenches,
connect
three
wire
assemblies (49) at terminals and two
wire assemblies (48) at terminals to
magnetic switch.
Apply silicone sealant over entire
connection.
Connect two wire assemblies (47 and
46) at connectors to starter lockout
relays.
Apply silicone sealant over entire
connection.
Using a 9/16 socket and socket
wrench handle, install clamp
(45),
washer (44) and bolt (43).
Using a flat tip screwdriver, connect
three
wire
assemblies (42) at
terminals to engine water temperature
switch.
Apply silicone sealant over entire
connection.
Go to sheet 12
5-36
|