5-1.
Starting Motor.
(Sheet 15 of 15)
ADJUSTMENT
Only personnel with training and
experience in handling potentially
hazardous
electrical
testing
procedures may perform the next
procedure. An insulating glove
and/or insulated tool should be
used.
93.
94.
95.
96.
97.
98.
99.
Momentarily touch jumper lead A from
battery negative to MTR terminal.
Drive will
shift into
cranking
position.
Push on drive to take up movement.
Measure pinion clearance. It should
be 0.36 inches.
Adjust pinion clearance, if required,
by turning locknut.
Remove three jumper leads.
Connect
lead assembly
(12) to
starting motor solenoid.
Install new gasket (2) and plug (1).
NOTE
Return M10A Forklift to original
equipment condition.
END OF TASK