TM  10-3930-643-34 ELECTRICAL  SYSTEM  MAINTENANCE. 5-1. Starting Motor.    (Sheet 12 of 15) ASSEMBLY 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. If removed, press new bushing (41) into  housing  (37). Prior to installation,    soak bushing in oil, Grade 3. Soak new wick (40) and new cap (39) in oil, Grade 3, then install. Lubricate  new  preformed  packing  (38) lightly with oil, Grade 3, then install. Using a 1/4”   socket head screw key, install housing (37), five bolts (36) and bolt (35) in starting motor housing  (70). Tighten bolts to 13 to 17 lb-ft. Install washer (34). Install four springs (32) in element holder (33). Using a flat tip screwdriver, install four brushes (31) and screws (30). Check that brushes (31) ride freely in  holder. Soak new bearing (28) in oil, Grade 3. If removed, press new bearing (28) into frame (29) with suitable driver and press. Soak new wick (27) and new cap (26) in oil, Grade 3, then install. Go to sheet 13 5-13