5-1.
Starting Motor. (Sheet 3 of 15)
DISASSEMBLY (cont)
7.
8.
9.
10.
11.
12.
13.
14.
NOTE
Starting motor frame and housings
must be match marked before dis-
assembly.
Using a 7/16 socket and socket
wrench handle,
remove four bolts
(18).
Remove items 19 thru 33 as an
assembly.
Use suitable driver and
hammer to tap around circumference of
frame (29).
Using a 3/4 open end wrench, remove.
nut (19), lock-washer (20),
(21) and bushing (22).
washer
Using a flat tip screwdriver, remove
three screws (23).
Separate frame (29), element holder
(33) and preformed packing (24).
Discard preformed packing (24).
Remove two insulators
(25) from
element holder (33).
Using an electric drill, drill hole
to pry out cap (26) and wick
(27)
from frame (29).
Discard cap (26)
and wick (27).
Removal of bearing from frame will
cause destruction of
bearing.
Remove
only if
inspection
indicates removal is necessary.
Inspect bearing (28).
Replace if
cracked, broken, grooved or scored.
Go to sheet 4