TM  10-3930-643-34 ENGINE,  FUEL,  EXHAUST  AND  COOLING  TROUBLESHOOTING  AND  MAINTENANCE. 4-15. Turbocharger and Piping. (Sheet 3 of 6) CLEANING/INSPECTION 7. Clean hoses (7 and 10) with cloth moistened  with  detergent. Dry  cleaning  solvent  P-D-680,  used for cleaning parts, is toxic and flammable. Use  only  in  well ventilated  areas. Wear  protective goggles and gloves. Do not smoke or allow open flames or sparks in areas where cleaning solvent is used or stored. Avoid contact with eyes, skin or clothing. If contact with eyes is made, flush with cold water and seek medical attention  immediately. If contact with skin or clothing is made, flush with cold water. If you become  dizzy  while  using  cleaning solvent, get fresh air immediately. COMPRESSED  AIR  HAZARD Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective chip guarding and personal protective equipment  (goggles/shield,  gloves, etc.). 8. Clean exterior of turbocharger (12) with cloth moistened with cleaning solvent  P-D-680. Allow to air dry. 9. Clean all other parts with cleaning solvent P-D-680. Dry thoroughly with  compressed  air. Refer to paragraph  2-8. 10. If turbocharger fails, check for small parts dropped into exhaust manifold. 11. Inspect all other parts. Refer to paragraph 2-9. Go to sheet 4 4-103