TM 10-3930-643-20
PREPARATION FOR MOVING AND STORAGE.
16-4.
Storage. (Sheet 3 of 4)
Servicing Engine During Storage
Six
22.
23.
24.
25.
26.
27.
month repeated
Perform steps
s e r v i c e:
1 though 5 of the Once-a-month repeated service.
WARNING
Due to the vapors given off by corrosion inhibitor oil, irritation of
eyes may occur and prolonged exposure should be avoided.
S p r a y i n s i d e o f c r a n k c a s e , t h r o u g h o i l f i l l e r p i p e , w i t h 0 . 5 o z of
volatile corrosion inhibitor oil for each quart of engine oil capacity.
Through a tapped hole in the intake manifold, spray 2 to 4 oz of VCI into
the air induction system.
Remove electrical lead from fuel solenoid switch and turn master switch in
the ON position. Crank the engine for 5 to 10 seconds.
Remove air intake cap and immediately seal engine crankcase breather tube,
e x h a u s t o u t l e t , e l e c t r i c al
intake.
Add 2.5 oz of VCI for each
spray inside of tanks with
capacity.
Slave Starting the Engine
components, fuel tank vent line and engine air
gallon of fuel in tanks or drain fuel tanks and
1-1/3 oz of VCI for each 10 gallons of tank
WARNING
Be sure the parking brake and transmission control lever is in the
p a r k p o s i t i o n b e f o r e s t a r t i n g t h e e n g i n e t o p r e v e n t a c c i d e n t al
movement of the machine.
CAUTION
When using an external electrical source to start the q achine, turn
the MASTER switch off and remove the key before
attaching
booster
c a b l e s .
This machine has a 24 volt starting system. Use only an equal voltage
for boost starting.
16-9
|