TM 10-3930-643-20
PREPARATION FOR MOVING AND STORAGE. (cont)
16-4.
Storage. (Sheet 2 of 4)
Servicing Engine During Storage
Once-a-month repeated service:
13.
Remove coverings from engine crankcase breather tube, exhaust outlet,
electrical components, fuel tank vent line and engine air intake.
I n s t a ll
the air intake cap.
14.
Check cooling system for leaks, loose connections and proper coolant
level. Refer to paragraph 4-27.
15.
Check engine oil level and add oil as requried. Refer to LO 10-3930-
643-12.
16.
Drain water from fuel tank.
Refer to paragraph 4-19.
17.
Using two personnel, install fully charged batteries.
Refer to paragraph
5 - 4 8.
Cranking engine should be limited to 30 second intervals.
18. Remove electrical lead from fuel solenoid switch and turn master switch in
the ON position. Crank engine until an oil pressure reading is indicated
on engine oil pressure gage.
19.
Start engine and run at low to medium speeds for 20 minutes, then shut off
engine.
20.
Remove air intake cap. Seal engine crankcase breather tube, exhaust
outlet, electrical components, fuel tank vent line and engine air intake.
21.
If M10A Forklift has been stored for a period of one year:
a. Fuel system must be completely drained and refilled with approved
d i e s e l f u e l.
Fuel filters must also be changed. Refer to paragraph
4-23.
b.
Engine oil must be drained then replaced with recommended lubricating
oil. Refer to LO 10-3930643-12.
Oil filters must also be replaced.
Refer to paragraph 4-11.
16-8
|