TM 10-3930-643-20
NON-ELECTRICAL GAGES MAINTENANCE. (cont)
15-2.
Air Pressure Gage. (sheet 2 of 3)
REMOVAL (cont)
3.
Using a flat blade screwdriver,
remove screw (4) and lock washer
( 5 ) .
NOTE
All wire must be tagged when
removed from connector. Indicate
whether wire is connected to pin-
type or socket-type connector.
4.
Disconnect wire assembly (6).
NOTE
Tag all hose and tube assemblies
before disconnecting to aid in
i n s t a l l a t i o n.
5.
Using a 7/16 open end wrench,
disconnect hose assembly (7).
6.
Remove elbow (8).
7.
Remove connector (9).
8 .
Using 3/4 and 9/16 open end
wrenches, remove reducer (10) and
t e e ( 1 1 ).
9.
Disconnect wire assembly (12).
10.
Remove lamp (13).
11.
U s i n g a 3 / 8 s o c k e t a n d s o c k et
wrench handle, remove two nuts (14)
and lock washers (15).
12.
Remove bracket (16).
13.
Remove gage (17).
Go to sheet 3