TM 10-3930-643-20
NON-ELECTRICAL GAGES MAINTENANCE.
15-1.
Air Cleaner Filter Indicator (Sheet 2 of 3)
CLEANING/INSPECTION
6.
C l e a n a i r f i l t e r c l e a n e r i n d i c a t or
(1) with mild detergent and water
s o l u t i o n.
Dry cleaning solvent P-D-680 used
for cleaning parts, is toxic and
f l a m m a b l e . U s e o n l y i n w e l l
ventilated areas. Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
u s e d o r s t o r e d . A v o i d c o n t a ct
w i t h e y e s , s k i n o r c l o t h i n g . If
contact with eyes is made, flush
with cold water and seek medical
attention immediately. If contact
with skin or clothing is
made,
f l u s h w i t h c o l d w a t e r . I f y ou
become dizzy while using cleaning
s o l v e n t , g e t
fresh
a ir
immediately.
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h ip
guarding and personal protective
equipment
( g o g g l e s / s h i e l d,
g l o v e s , e t c . ).
7.
Clean holes in orificed adapter (2)
with .020 mechanics wire.
8.
Clean all other parts with cleaning
solvent P-D-680.
Dry thoroughly
with compressed air.
R e f e r t o
paragraph 2-8.
9.
I n s p e c t a l l p a r t s . R e f e r t o p a r a-
graph 2-9.
Go to sheet 3