TM 10-3930-643-20
HYDRAULIC SYSTEM
14-7.
Hydraulic
SERVICE
15.
Install new
TROUBLESHOOTING AND MAINTENANCE.
Reservoir and Filter (Sheet 4 of 6)
preformed packing (6),
indicator (7) and new preformed
packing (8) into new filter element
( 5 ) .
16.
Screw filter element (5) into base
assembly by turning clockwise.
NOTE
Steps 16 through 21 are to be
d o n e o n l y i f i n s p e c t i o n of
f i l t e r s o n b o t t o m o f r e s e r v o ir
proves cleaning of these filters
is necessary.
17.
Remove filler cap (1a) and gasket
( 9 ).
Remove all gasket material
from mounting surfaces.
Dry cleaning solvent P-D-680 used
for cleaning parts, is toxic and
f l a m m a b l e . U s e o n l y i n w e ll
ventilated areas. Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
used or stored.
A v o i d c o n t a ct
w i t h e y e s , s k i n o r c l o t h i n g . If
contact with eyes is made, flush
with cold water and seek medical
attention immediately. If contact
with skin or clothing is
made,
f l u s h w i t h c o l d w a t e r . I f y ou
become dizzy while using cleaning
s o l v e n t , g et
f r e sh
a ir
immediately.
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h i p
guarding and personal protective
equipment
( g o g g l e s l s h i e l d,
g l o v e s , e t c . ).
Go to sheet 5
14-27
|