TM   10-3930-643-20 HYDRAULIC   SYSTEM   TROUBLESHOOTING   AND   MAINTENANCE. 14-3.   Fork   Control   Lever   Assemblies.   (Sheet   4   of   7) DISASSEMBLY 21. Using  a  9/16”  open  end  wrench, remove   knob   (33)   and   nut   (34). 22. Using   a   7/16”   open   end   wrench, remove   fitting   (35). 23. Remove   two   bearings   (36)   from   lever ( 3 7 ). CLEANING/INSPECTION •  TOXIC/FLAMMABLE Dry   cleaning solvent    P-D-680, used   for   cleaning   parts,   is   toxic and   flammable. Use   only   in   well ventilated areas. Wear protective   goggles   and   gloves. Do   not   smoke   or   allow   open   flames or  sparks  in  areas  where  cleaning 24. 25. solvent   is   used   or   stored. Avoid contact   with   eyes, s k i n    o r c l o t h i n g. If   contact   with   eyes is   made,   flush   with   cold water and seek medical attention immediately. I f    c o n t a c t    w i th skin   or   clothing   is   made, f l u sh with   cold   water. If   you become d i z z y    w h i l e    u s i n g    c l e a n i n g s o l v e n t ,    g et fresh a i r immediately. •  COMPRESSED  AIR  HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h i p guarding   and   personal   protective equipment ( g o g g l e s / s h i e l d, g l o v e s ,    e t c . ). C l e a n    a l l    p a r t s    w i t h    c l e a n i ng solvent   P-D-680. Dry thoroughly with   compressed   air. R e f e r    to paragraph   2-8. Inspect   all   parts. R e f e r    t o    p a r a - graph   2-9. Go  to  sheet  5 14-11

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business