TM   10-3930-643-20 BODY,  CHASSIS  AND  HULL  ACCESSORY  ITEMS  TROUBLESHOOTING  AND  MAINTENANCE. 13-1. Accessory   Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION c . DEFROSTER  FAN  FAILS  TO  OPERATE. Check   all   electrical   connections. If   connections   are   loose   or   damaged,   correct   them. If   connections   are   good,   refer   to   paragraph   13-8   for   procedure f o r repair   and   replacement. Inspect   electrical   harness   and   check   for   continuity. d. HORN  DOES  NOT  SOUND. Step   1. Check   air   pressure   gage   on   instrument   panel. If   air   pressure   is   not   in   RUN   area,   wait   for   pressure   to   build   up. If  air  pressure  is  within  RUN  area,  go  to  step  2. Step  2. Check   air   hose   connection   to   horn   valve. If   hoses   is   damaged,   repair   or   replace,   refer   to   paragraph   13-4. If   hose   is   good,   go   on   to   step   3. Step   3. Check   horn   valve   for   proper   operation. If   valve   is   faulty,   repair   or   replace.   Refer   to   paragraph   13-3. If   valve   is   good,   go   to   step   4. Step  4. Check   horn,   refer   to   paragraph   13-2. Repair   or   replace   if   necessary. 13-3

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business