TM 10-3930-643-20
FRAME AND TOWING ATTACHMENTS TROUBLESHOOTING AND MAINTENANCE (Cont)
11-6.
Bolster Lines and Fittings. (Sheet 3 of 3)
CLEANING/INSPECTION (cont)
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h ip
guarding and personal protective
equipment (goggles/shield, gloves,
etc.).
5.
Clean all parts with cleaning
solvent P-D-680.
Dry thoroughly
with compressed air.
Refer to
paragraph 2-8.
6.
Inspect all parts. Refer to para-
graph 2-9.
INSTALLATION
7.
Using a 5/16 open end wrench,
install two elbows (8), tubes (7)
and elbows (6) inside bolster frame.
8.
Install clamp (5), washer (4) and
nut (3).
9 .
Install two grease fittings (2) in
couplings (1).
10.
Install two couplings (1) in bolster
frame.
NOTE
Return M10A Forklift to original
equipment condition.
END OF TASK
11-26
|