Ground Driven Steering Pump (S/N 2000 and below). (Sheet 7 of 8)
INSTALLATION (cont)
Before starting vehicle, prime
ground driven steering pump.
Failure to follow this procedure
c o u l d r e s u l t i n d a m a g e to
equipment.
44.
46.
47.
F i l l h y d r a u l i c r e s e r v o i r . R e f e r to
paragraph 14-7.
Using a 9/16 socket and socket
wrench handle, loosen four bolts
(15) and two flange halves (16) only
to extent necessary to allow air and
a small amount of fluid to escape.
Tighten two flange halves (16) and
four bolts (15).